Split Core Current Transformers

Split Core Current Transformers

In today’s complex electrical systems, accurate and reliable current measurement is essential for efficient power monitoring, protection, and control. YADA’s Split Core Current Transformer (CT) is a cutting-edge solution that delivers precision, ease of installation, and robust performance across a wide range of applications. Whether you are working with industrial power systems, commercial buildings, or renewable energy installations, our Split Core CTs provide the flexibility and accuracy needed for reliable energy management and monitoring.

Designed to fit into existing systems with minimal disruption, YADA’s Split Core CTs allow for non-invasive current measurement, making them the perfect choice for retrofit projects, energy audits, and any scenario requiring accurate current monitoring without interrupting existing wiring.

Key Features

  • Non-Invasive Installation: Quick, easy setup with no need to disconnect cables or shut down the system.

  • High-Precision Measurement: Accurate current measurement for a wide range of applications.

  • Wide Current Range: Suitable for both low and high current applications (from milliamps to thousands of amps).

  • Durable and Compact: Resilient to harsh environments, with a compact design that fits in tight spaces.

  • Electrical Isolation: High electrical isolation to ensure safety and protect systems.

  • Cost-Effective: Efficient installation and long-lasting performance reduce operational costs.

Application

  • Energy Management and Metering: Monitor energy consumption and performance in industrial facilities, commercial buildings, and residential complexes.

  • Power Distribution Systems: Measure and monitor the flow of electricity through power distribution systems, ensuring optimal efficiency and reliability.

  • Renewable Energy Systems: Used in solar, wind, and other renewable energy setups for accurate monitoring of power generation and distribution.

  • Industrial Automation: Provide accurate current measurement for motors, pumps, and other industrial equipment to optimize energy usage and reduce downtime.

  • Electric Vehicle (EV) Charging Stations: Monitor current flow to ensure safe and efficient operation of EV charging infrastructure.

  • Overcurrent Protection Systems: Enhance safety by providing accurate current measurements for overcurrent protection and fault detection in electrical circuits.

Structure

Product Selection

Model
Input current
Output current
Aperture(mm)
Accuracy
SCT24L-5K-50
50A
10mA
24
0.5
SCT24L-5K-100
100A
20mA
24
0.5
SCT24L-5K-150
150A
30mA
24
0.5
SCT24L-5K-200
200A
40mA
24
0.5
SCT24L-5K-250
250A
50mA
24
0.5
SCT24L-5K-300
300A
60mA
24
0.5

 

 

Model
Rated Input/Output
Accuracy
Withstand Voltage
Threading Aperture
CT2404L-5K-50
50A/10mA
0.2, 0.2S
4.0kV
Φ16mm / 24.5×4mm
CT2404L-5K-100
100A/20mA
0.2, 0.2S
4.0kV
Φ16mm / 24.5×4mm
CT2404L-5K-150
150A/30mA
0.2, 0.2S
4.0kV
Φ16mm / 24.5×4mm
CT2404L-5K-200
200A/40mA
0.2, 0.2S
4.0kV
Φ16mm / 24.5×4mm

 

Model
Aperture
Rated input/output
Accuracy
CTF16L-2k-50
16mm
50A/25mA
0.5
CTF16L-2k-100
16mm
100A/50mA
0.5
CTF16L-2k5-50
16mm
50A/20mA
0.5
CTF16L-2k5-100
16mm
100A/40mA
0.5
CTF16L-3k-60
16mm
60A/20mA
0.5
CTF16L-3k-120
16mm
120A/40mA
0.5
CTF16L-5k-50
16mm
50A/10mA
0.5
CTF16L-5k-100
16mm
100A/20mA
0.5

 

Item
Specification
Model
CTF24 / CTF35 / CTF50
Input Current
100A – 1000A
Secondary Output
5A or 1A
Accuracy Class
0.5, 1.0, 3.0
Rated Voltage
0.66 kV
Isolation Voltage
AC 3.0 kV/min (secondary to ground)
Structure
Split-core (openable toroidal)
Certification
CE, Standard: EN 61010-1:2010+A1:2019, GB/T 20840.2-2014
Application
Energy monitoring, single-phase circuits, industrial control systems
 
Model
Rated Input Current
Rated Output Current
Dimension(mm)
W
H
D
a
e
YDBH0.66-30Ⅱ-G
100A~600A
5A / 1A
62
101
45
32
32
YDBH0.66-40Ⅱ-G
150A~1200A
78
106
41
42
32
YDBH0.66-50Ⅱ-G
150A~1500A
87
116
45
52
32
YDBH0.66-60Ⅱ-G
300A~2500A
102
128
45
62
32
YDBH0.66-60×50Ⅱ-G
300A~2500A
102
145
45
62
52
YDBH0.66-80Ⅱ-G
400A~3000A
117
122
45
82
32
YDBH0.66-80×50Ⅱ-G
400A~3000A
145
158
50
102
52
YDBH0.66-100Ⅱ-G
500A~4000A
145
128
45
102
32
YDBH0.66-100×50Ⅱ-G
500A~4000A
145
158
50
102
52
YDBH0.66-100×80Ⅱ-G
500A~4000A
152
193
55
102
82
YDBH0.66-120Ⅱ-G
800A~5000A
174
171
48
122
52
YDBH0.66-120×70Ⅱ-G
1000A~5000A
160
196
60
122
72
YDBH0.66-130Ⅱ-G
1000A~5000A
176
163
50
135
55
YDBH0.66-150Ⅱ-G
1000A~6000A
210
179
55
155
55
YDBH0.66-180Ⅱ-G
1500A~6000A
239
184
60
185
55
YDBH0.66-220Ⅱ-G
1500A~6300A
280
193
60
225
55
YDBH0.66-260Ⅱ-G
1500A~6300A
320
194
60
265
55
YDBH0.66-260×100Ⅱ-G
2000A~7500A
308
221
63
265
105
Model Specification
Rated Input Current
Rated Output Current
Dimensions (mm)
W*L*H
YDBH0.66-30Ⅱ-B
100A~600A
5A / 1A
62*101*45
YDBH0.66-40Ⅱ-B
150A~1200A
78*106*41
YDBH0.66-50Ⅱ-B
150A~1500A
87*116*45
YDBH0.66-60Ⅱ-B
300A~2500A
102*128*45
YDBH0.66-60×50Ⅱ-B
300A~2500A
102*145*45
YDBH0.66-80Ⅱ-B
400A~3000A
117*122*45
YDBH0.66-80×50Ⅱ-B
400A~3000A
120*144*45
YDBH0.66-100Ⅱ-B
500A~4000A
145*128*45
YDBH0.66-100×50Ⅱ-B
500A~4000A
145*158*50
YDBH0.66-100×80Ⅱ-B
600A~4000A
152*193*55
YDBH0.66-120Ⅱ-B
800A~5000A
174*171*48
YDBH0.66-120×70Ⅱ-B
1000A~5000A
160*196*60
YDBH0.66-130Ⅱ-B
1000A~5000A
176*163*50
YDBH0.66-150Ⅱ-B
1000A~6000A
210*179*55
YDBH0.66-180Ⅱ-B
1500A~6300A
239*184*60
YDBH0.66-220Ⅱ-B
1500A~6300A
280*193*60
YDBH0.66-260Ⅱ-B
1500A~6300A
320*194*60
YDBH0.66-260×70Ⅱ-B
2000A~7500A
308*221*63
Model
Rated Input Current
Rated Output Current
Rated Burden
Accuracy Class
YDKH 0.66-60*30×20II
200A–1500A
        5A/1A

1.5VA~ 15VA

0.2,0.5,1.0

YDKH0.66-60×40II-B
300A–2500A
YDKH0.66-80×40II-B
600A–4000A
YDKH0.66-100×40II-B
1000A–5000A
YDKH0.66-130×40II-B
1000A–5000A
YDKH0.66-140×40II-B
1000A–5000A
YDKH0.66-160×40II-B
1000A–5000A

Model
Rated Input Current
Rated Output Current
Rated Burden
Accuracy Class
Dimensions (mm)
YDBH1.2-100
1000A–4000A

5A/1A

15VA~ 40VA

0.1 / 0.2 / 0.2S

W166 × H143 × D43
YDBH1.2-120
2000A–5000A
W186 × H160 × D45
YDBH1.2-150
2000A–6300A
W227 × H170 × D52

Certificates

With UL, CE Certified.

 

Photos on site

Why Choose YADA’s Split Core Current Transformer (CT)?

  1. Non-Invasive and Easy Installation: YADA’s Split Core CTs feature a split-core design, which allows for quick, easy installation without the need to disconnect the existing cables or shut down the system. This non-invasive installation reduces downtime and labor costs, making it an ideal solution for retrofit applications.

  2. Accurate and Reliable Measurement: YADA’s Split Core CTs provide high-precision current measurement with a wide range of current ratings, ensuring accurate data for energy monitoring, protection, and control. Our transformers are designed for reliable performance even under challenging conditions, ensuring continuous and consistent monitoring.

  3. Wide Current Range: Our Split Core CTs are capable of measuring both low and high currents (from a few milliamps to several thousand amps), making them highly versatile for use in various industries, including industrial automation, power distribution, and renewable energy applications.

  4. Compact and Durable Design: The compact design of YADA’s Split Core CTs allows them to fit into tight spaces while maintaining high durability. Built to withstand harsh environmental conditions, our transformers are resistant to vibration, high temperatures, and electromagnetic interference, making them perfect for industrial settings and outdoor applications.

  5. High Safety Standards: With excellent electrical isolation, YADA’s Split Core CTs offer superior safety and protection for personnel and equipment. Our products meet global safety and performance standards, ensuring they can be safely used in high-voltage systems and high-risk environments.

  6. Cost-Effective and Efficient: By reducing the need for system downtime during installation, YADA’s Split Core CTs minimize operational disruptions, ultimately saving time and money. Their ease of integration and long-lasting durability make them a cost-effective solution for long-term power monitoring.

Why YADA?

As a leader in the field of energy monitoring solutions, YADA Electronics is committed to providing innovative, reliable, and cost-effective products that enhance power management efficiency and safety. Our Split Core Current Transformers are designed for easy installation, long-lasting performance, and superior accuracy, making them the ideal choice for diverse energy management and monitoring applications.

Whether you’re working on a new installation or retrofitting existing systems, YADA’s Split Core CTs offer the precision, flexibility, and reliability you need to optimize your energy management systems.

For more information or to discuss how our Split Core Current Transformers can be integrated into your systems, please don’t hesitate to contact us.

something the matter? Contact us now!