Surge Protection Device

Surge protection devices from YADA Electronics — a Guangdong-based manufacturer (Beijing Stock Exchange: 920556) building AC and DC SPDs for EV charging cabinets, solar PV strings and industrial distribution. This category holds 6 models: AC units rated 40 kA (8/20 μs) with <25 ns response, and a DC Type 2 unit for 1000 V / 1200 V DC PV arrays. All certified CE, CB and TUV.

Buying Surge Protection From YADA — Verified Facts

  • CE, CB and TUV certified across the range, produced by Guangdong Yada Electronics Co., Ltd. — founded 1994, a National High-Tech Enterprise listed on the Beijing Stock Exchange (920556).
  • AC surge capacity up to 40 kA (8/20 μs) at nominal 220 V / 380 V.
  • Response time under 25 ns — fast enough to clamp before sensitive electronics see the transient.
  • Low residual voltage 1.8 kV on the YDF40-385/4+0 — the figure that determines what survives downstream.
  • Protection modes L-N, L-PE and N-PE across the AC range.
  • DC PV protection: Ucpv 1000 V / 1200 V DC, In 20 kA, Imax 40 kA, Up 4.0 / 4.5 kV, Type 2, 3P.
  • Operating range −40 °C to +80 °C — covers outdoor charger cabinets in most climates.
  • 35 mm DIN-rail mounting across the range.
  • Configurations 1+1, 3+1 and 4+0 to match the earthing arrangement.

Configuration Follows The Earthing System, Not Preference

The 1+1, 3+1 and 4+0 designations are not product tiers — they describe how the protection modules are arranged between live conductors, neutral and earth. Choosing the wrong arrangement for the site’s earthing system leaves a path unprotected no matter how high the kA rating is.

Configuration Model Arrangement Typical Use
1+1 YDF40-385/1+1 One protection module line-to-neutral plus one neutral-to-earth Single-phase supplies to EV chargers and small cabinets.
3+1 YDF40-385/3+1 Three line-to-neutral modules plus one neutral-to-earth Three-phase DC charger cabinets on TT and TN-S systems.
4+0 YDF40-385/4+0 Four modules direct to earth, low residual voltage 1.8 kV Three-phase installations needing the lowest let-through voltage.
DC Type 2 DC 1000 V / 1200 V SPD 3P, Ucpv 1000/1200 V, Up 4.0/4.5 kV Solar PV strings on the DC side of the inverter.

Surge Protection Technical Specifications

Parameter Specification
AC surge capacity Up to 40 kA (8/20 μs)
AC nominal voltage 220 V / 380 V
AC protection modes L-N, L-PE, N-PE
Response time < 25 ns
Residual voltage 1.8 kV (YDF40-385/4+0)
DC voltage (Ucpv) 1000 V DC, 1200 V DC
DC In / Imax 20 kA / 40 kA
DC protection level (Up) 4.0 kV, 4.5 kV
DC type Type 2, 3P
Temperature range −40 °C to +80 °C
Mounting 35 mm DIN rail
Certification CE, CB, TUV

Typical Applications

  • EV charging cabinets — both AC and DC charger enclosures, where a single strike can destroy the power module.
  • Solar PV arrays — DC Type 2 protection between the strings and the inverter.
  • Outdoor distribution boards — the −40 °C to +80 °C range covers unheated enclosures.
  • Telecom and monitoring cabinets — protecting the supply to instrumentation.
  • Industrial switchboards — coordinated protection downstream of the main incomer.

How To Select A Surge Protection Device

  1. Identify the earthing system (TT, TN-S, TN-C-S) — this determines whether you need 1+1, 3+1 or 4+0.
  2. Confirm AC or DC. A PV string on the DC side needs a DC-rated SPD; an AC device fitted there will not interrupt DC arcs safely.
  3. Check the voltage rating against the open-circuit array voltage at the lowest expected temperature, not the nominal figure.
  4. Compare the protection level (Up) with the withstand of the equipment you are protecting — a 4.0 kV Up is useless in front of a 2.5 kV-rated device.
  5. Set the discharge current from the exposure. 40 kA suits most secondary protection; direct-strike locations need coordinated Type 1 upstream.
  6. Confirm DIN-rail space — 3P and 4-module devices need the width allowed for.

Frequently Asked Questions

What is the difference between the 1+1, 3+1 and 4+0 versions?

They describe how protection modules are arranged between live conductors, neutral and earth. The correct choice follows the site’s earthing system — it is not a performance tier.

Can an AC SPD be used on the DC side of a solar array?

No. DC has no zero crossing, so an AC device cannot safely interrupt the follow current. Use the DC Type 2 unit rated Ucpv 1000 V or 1200 V.

Why does residual voltage matter more than kA rating?

The kA rating says how much energy the device survives; the residual (let-through) voltage says what reaches your equipment. The YDF40-385/4+0 clamps to 1.8 kV, which is what protects sensitive electronics downstream.

Are these suitable for outdoor cabinets?

Yes — the range is specified from −40 °C to +80 °C, which covers unheated outdoor enclosures in most climates.