YDi50P-N is a networked DC energy monitoring terminal that combines 800V DC voltage measurement, Hall-based current measurement, bidirectional energy metering, historical data recording, alarm management and Modbus communication for modern DC power systems.
YDi50P-N Core Technical Data
| Category | Parameter | YDi50P-N Specification |
| Product Type | Product | Intelligent DC Energy Meter |
| Application | Typical Applications | DC Distribution, EV Charging, BESS, Telecom Power, Data Center DC Systems |
| DC Voltage | Rated Voltage | 800V DC |
| Input Method | Direct Voltage Input | |
| Overvoltage Capacity | 1.2 × Rated Voltage Continuous | |
| DC Current | Current Input | Hall Sensor Input |
| Hall Sensor Output | 4V Secondary Output | |
| Measurement Method | External Hall Current Sensor | |
| Measurement | DC Voltage | Voltage Measurement |
| DC Current | Current Measurement | |
| DC Power | Active Power Measurement | |
| Energy Metering | Energy Direction | Forward & Reverse |
| Energy Measurement | Bidirectional DC Energy Metering | |
| Accuracy | Voltage Accuracy | ±0.2% / ±0.5% |
| Current Accuracy | ±0.2% / ±0.5% | |
| Power Accuracy | ±0.5% / ±1.0% | |
| Energy Accuracy | ±0.5% / ±1.0% | |
| Demand | Maximum Demand | Power & Current Demand |
| Demand Period | 1–60 min | |
| Data Logging | Monthly Energy Data | 12 Months |
| Annual Energy Data | 5 Years | |
| Event Recording | SOE Records | Up to 50 Events |
| Alarm | Monitoring | Over/Under Voltage, Over Current, Overload, Temperature |
| Communication | RS485 | Modbus RTU |
| Ethernet | Modbus TCP/IP | |
| RS485 Speed | 1200–38400 bps | |
| Ethernet Speed | 10/100 Mbps | |
| Digital Input | DI | Up to 4 DI |
| Relay Output | DO | 2 Relay Outputs |
| Sensor Power Supply | Hall Sensor Supply | DC ±12V |
| Installation | Mounting | Panel Mount |
| Dimensions | Meter Size | 98 × 98 × 80.8 mm |
| Panel Cutout | Installation Opening | 92 × 92 mm |
| Operating Temperature | Temperature Range | -20°C to +70°C |
| Storage Temperature | Storage Range | -40°C to +70°C |
| Humidity | Relative Humidity | 5–95% RH |
| Altitude | Maximum Altitude | ≤2000 m |
YDi50P-N — 5 Core Selling Points
1. Up to 800V DC Direct Voltage Measurement,YDi50P-N supports direct DC voltage measurement up to 800V, providing accurate and reliable electrical data for high-voltage DC distribution, EV charging, battery storage, and other DC power systems.
2. Hall Sensor Input for High-Current DC Monitoring,YDi50P-N uses an external Hall current sensor with a 4V secondary output, enabling accurate and flexible current measurement for high-current DC applications while simplifying system integration.
3. Bidirectional DC Power & Energy Metering , YDi50P-N measures both forward and reverse DC power and energy, making it ideal for applications with bidirectional energy flow such as battery storage, EV charging, and DC microgrid systems.
4. RS485 & Ethernet for Seamless EMS Integration, With RS485 Modbus RTU and Ethernet Modbus TCP/IP communication, the YDi50P-N enables reliable remote data transmission and seamless integration with EMS, SCADA, PLC, and other energy management platforms.
5. Advanced Data Logging & Intelligent Alarm Monitoring, YDi50P-N records historical energy data and abnormal events while supporting configurable voltage, current, overload, and other alarms for continuous monitoring and improved DC system reliability.
FAQ
Q1. What is the maximum direct DC voltage?
Up to 800V DC as standard. Other voltage ratings can be specified when ordering.
Q2. How is DC current measured?
Through an external Hall current sensor with a 4V secondary output.
Q3. Can it measure bidirectional energy?
Yes. It measures and stores both forward and reverse DC energy.
Q4. Can it connect to an EMS?
Yes. It supports RS485 Modbus RTU and Ethernet Modbus TCP/IP.
Q5. Can it monitor breaker status?
Yes. Up to 4 digital inputs are available depending on configuration.
Q6. Does it support alarm output?
Yes. Two relay outputs are available in the relevant configuration.
Q7. How much historical energy data can it store?
12 months of monthly data and 5 years of annual data.
Q8. Is it suitable for EV charging and BESS?
Yes. Its 800V DC measurement, Hall sensor interface, bidirectional energy metering and network communication make it well suited to these DC energy applications.
YDi50P-N Intelligent DC Energy Meter VS Ordinary DC Energy Meter
The YDi50P-N is designed not only to measure DC energy consumption, but also to provide high-voltage DC measurement, bidirectional energy metering, Hall sensor current measurement, data recording, alarms, and network communication for modern DC power systems.
| Feature | Ordinary DC Energy Meter | YDi50P-N Intelligent DC Energy Meter |
|---|---|---|
| Product Positioning | Basic DC energy measurement | Intelligent DC power and energy monitoring |
| DC Voltage | Basic DC voltage measurement | Up to 800V DC |
| Current Measurement | Direct or basic sensor input | External Hall Sensor Input |
| High Current Monitoring | Limited flexibility | Suitable for high-current DC systems |
| Energy Direction | Usually single-direction | Forward & Reverse Energy Metering |
| Power Measurement | Basic DC power | Accurate DC Power Measurement |
| Energy Accuracy | Typically basic metering accuracy | Up to ±0.5%* |
| Power Quality / Electrical Monitoring | Limited | Voltage, Current, Power and Energy Monitoring |
| Demand Measurement | Usually unavailable | Maximum Power & Current Demand |
| Historical Data | Limited or unavailable | 12-Month Monthly + 5-Year Annual Data |
| Event Recording | Usually unavailable | Up to 50 SOE Events |
| Alarm Functions | Basic or none | Voltage, Current, Overload & Temperature Alarms |
| Digital Inputs | Usually unavailable | Up to 4 Digital Inputs |
| Relay Outputs | Usually unavailable | 2 Relay Outputs |
| RS485 Communication | Optional / Basic | Modbus RTU |
| Ethernet Communication | Rare | Modbus TCP/IP |
| EMS / SCADA Integration | Limited | Direct System Integration |
| Application | Basic DC metering | EV Charging, BESS, DC Distribution, Telecom & Data Center |
| Energy Management | Energy reading | Monitoring, Recording, Analysis & Integration |