What Is a Current Transformer?

A current transformer (CT) is an electrical measurement device that converts high AC currents into a smaller, standardized current signal that can be safely measured by electrical meters, protection devices, and monitoring systems.

Current transformers allow engineers to monitor large electrical currents without directly connecting sensitive measurement equipment to high-current circuits.

They are widely used in:

  • Energy meters
  • Power monitoring systems
  • Industrial automation
  • Solar PV systems
  • EV charging infrastructure
  • Data centers
  • Smart buildings

Quick Answers (Featured Snippet Optimization)

What does a current transformer do?

A current transformer reduces high electrical current to a lower measurable current, typically 5A, 1A, or milliamp-level output, allowing safe measurement and monitoring.


Why are current transformers used?

Current transformers are used because directly measuring high currents is unsafe, expensive, and technically difficult.

CTs provide:

  • Electrical isolation
  • Safe measurement
  • Accurate monitoring
  • Easy integration with meters and control systems

What is the difference between a CT and a normal transformer?

A normal transformer transfers electrical energy between circuits, while a current transformer is specifically designed to measure current and provide a proportional output signal.


Where are current transformers installed?

Common locations include:

  • Electrical switchboards
  • Distribution panels
  • Power transformers
  • Solar inverter systems
  • EV charging stations
  • Data center power distribution units

Introduction

Electricity measurement is the foundation of modern energy management.

However, measuring the current flowing through industrial electrical systems is not always simple.

Large facilities such as factories, data centers, renewable energy plants, and commercial buildings often operate with hundreds or thousands of amperes.

Connecting measurement instruments directly to these high-current circuits would be:

  • Unsafe
  • Expensive
  • Difficult to maintain
  • Technically impractical

This is where Current Transformers (CTs) become essential.

A current transformer provides a safe and accurate method to measure electrical current by converting high primary current into a smaller secondary signal that can be monitored by:

  • Energy meters
  • Power meters
  • Protection relays
  • Power quality analyzers
  • Energy management systems (EMS)

Today, current transformers are one of the most important components in modern electrical measurement and intelligent energy monitoring systems.


Chapter 1 — What Is a Current Transformer?

A Current Transformer (CT) is a type of instrument transformer designed to measure alternating current (AC).

Its primary function is:

Convert high electrical current into a lower proportional current signal while providing electrical isolation between the power circuit and measurement equipment.


Basic Concept

A CT operates based on electromagnetic induction.

When current flows through the primary conductor, it creates a magnetic field inside the CT core.

This magnetic field induces a proportional current in the secondary winding.

The measurement system then calculates the actual primary current based on the CT ratio.


Simple Example

Suppose a CT has a ratio:

400A / 5A

This means:

  • Primary current: 400A
  • Secondary output: 5A

If the measured secondary current is:

2.5A

The actual primary current is:

200A


Chapter 2 — Why Are Current Transformers Important?

Without CTs, monitoring high-current electrical systems would be extremely challenging.


1. Electrical Safety

CTs isolate measurement devices from dangerous high-voltage and high-current circuits.

Engineers can monitor electrical systems without directly connecting instruments to high-current conductors.


2. Accurate Energy Measurement

Modern energy meters rely on CTs to measure:

  • Current
  • Power
  • Energy consumption
  • Demand
  • Load characteristics

The accuracy of the CT directly affects energy measurement accuracy.


3. Cost Reduction

Instead of designing meters capable of handling thousands of amperes, manufacturers use CTs to provide standardized measurement signals.

This makes monitoring systems:

  • Smaller
  • Safer
  • More affordable

4. Easy System Expansion

CTs allow existing electrical systems to be upgraded without replacing main power equipment.

This is especially valuable for:

  • Factory energy retrofits
  • Building upgrades
  • Data center expansion

Chapter 3 — How Does a Current Transformer Work?

A current transformer consists mainly of:

  • Magnetic core
  • Primary conductor
  • Secondary winding
  • Insulation structure
  • Terminal connection

Basic Working Process

High Current Circuit

        │

        â–¼

Primary Conductor

        │

        â–¼

Magnetic Field Generated

        │

        â–¼

Secondary Winding

        │

        â–¼

Low Current Output Signal

        │

        â–¼

Energy Meter / Monitoring System

Primary Side

The primary side carries the actual current being measured.

It may be:

  • A single conductor passing through the CT core
  • A built-in primary winding
  • A busbar passing through a window-type CT

Examples:

  • 100A
  • 400A
  • 1000A

Secondary Side

The secondary side provides a standardized output.

Common outputs:

5A Output

Traditional industrial measurement standard.

Applications:

  • Protection systems
  • Large electrical equipment

1A Output

Common for long-distance transmission and high-accuracy applications.

Advantages:

  • Lower cable losses
  • Better for long wiring distances

mA Output

Used in modern electronic measurement systems.

Examples:

  • 10mA
  • 20mA
  • 50mA
  • 100mA

Applications:

  • Smart meters
  • Compact energy monitoring devices

Chapter 4 — Main Types of Current Transformers

Current transformers can be classified according to structure and application.


1. Solid Core Current Transformer

A traditional CT design where the magnetic core is a closed ring.

Advantages

  • High accuracy
  • Good stability
  • Low phase error

Applications

  • New electrical installations
  • Switchgear
  • Protection systems

2. Split Core Current Transformer

A split core CT has a hinged or removable magnetic core that allows installation without disconnecting the main conductor.

Advantages

  • No power interruption
  • Easy retrofit installation
  • Faster commissioning
  • Reduced installation cost

Applications:

  • Energy monitoring upgrades
  • Existing buildings
  • Industrial retrofit projects

YADA SCT24L and SCT40L series are designed for these types of applications.


3. Residual Current Transformer (ZCT)

Residual current transformers detect leakage current caused by insulation faults.

Applications:

  • Ground fault protection
  • Leakage monitoring
  • RCD systems

4. High Accuracy Metering CT

Designed for precise energy measurement.

Applications:

  • Revenue metering
  • Utility measurement
  • High-accuracy monitoring

Chapter 5 — Current Transformer Applications

Industrial Energy Monitoring

Factories use CTs to monitor:

  • Production equipment
  • Motors
  • Compressors
  • Distribution feeders

Benefits:

  • Energy optimization
  • Equipment analysis
  • Cost reduction

Smart Buildings

CTs support:

  • Tenant energy management
  • Building automation
  • EMS platforms

Solar PV Systems

CTs measure:

  • Solar inverter output
  • Grid interaction
  • Energy generation

EV Charging Infrastructure

CTs enable:

  • Charger load monitoring
  • Dynamic load balancing
  • Energy billing

Data Centers

CTs monitor:

  • UPS systems
  • PDUs
  • Branch circuits

Supporting:

  • Power reliability
  • Capacity planning
  • Energy efficiency

Chapter 6 — Current Transformer and Energy Management Systems

Modern CTs are no longer isolated measurement devices.

They are key components in intelligent energy ecosystems.

Typical architecture:

Electrical Load

↓

Current Transformer

↓

Energy Meter

↓

RS485 Modbus

↓

EMS Platform

↓

Energy Analytics

CTs provide the current data required for:

  • Real-time monitoring
  • Energy reporting
  • Carbon management
  • Predictive maintenance

Chapter 7 — Current Transformer Selection Basics

Choosing the correct CT requires evaluating:

1. Current Ratio

Example:

100A/5A

200A/5A

400A/5A


2. Accuracy Class

Common classes:

  • Class 0.2
  • Class 0.5
  • Class 0.5S
  • Class 1.0

Higher accuracy is required for:

  • Billing
  • Precision monitoring

3. Installation Method

Choose according to project requirements:

Installation Recommended CT
New panel Solid Core CT
Retrofit Split Core CT
Leakage detection ZCT
Compact monitoring Mini CT

4. Certification Requirements

Industrial CT projects often require:

  • IEC compliance
  • CE
  • UL
  • RoHS

Chapter 8 — Understanding Current Transformer Ratio

The CT ratio is one of the most important parameters when selecting a current transformer.


What Is CT Ratio?

The CT ratio represents the relationship between:

  • Primary rated current
  • Secondary rated current

The formula is:

CT Ratio = Primary Current / Secondary Current


Common CT Ratios

Primary Current Secondary Current CT Ratio
50A 5A 50/5A
100A 5A 100/5A
200A 5A 200/5A
400A 5A 400/5A
600A 5A 600/5A

Example

A factory feeder has a maximum operating current of:

400A

A suitable CT could be:

400A/5A

If the actual current is:

200A

The CT secondary output becomes:

2.5A

The energy meter calculates the actual current using the configured CT ratio.


Why Correct CT Ratio Selection Matters

Choosing an incorrect ratio creates measurement problems.


CT Ratio Too Large

Example:

Actual load:

80A

Selected CT:

400A/5A

Problems:

  • Poor measurement resolution
  • Lower accuracy at low loads
  • Reduced energy monitoring quality

CT Ratio Too Small

Example:

Actual load:

500A

Selected CT:

200A/5A

Problems:

  • CT overload
  • Measurement error
  • Possible equipment damage

Best Practice for CT Ratio Selection

The ideal CT should operate near:

60%–80% of rated primary current

Example:

Expected load:

250A–300A

Recommended CT:

400A/5A

This provides:

  • Better accuracy
  • Operating margin
  • Longer service life

Chapter 9 — Current Transformer Accuracy Class Explained

Accuracy is one of the most important specifications for electrical measurement.

A CT with poor accuracy can cause:

  • Incorrect energy calculations
  • Billing errors
  • Wrong load analysis
  • Inefficient energy management

What Is CT Accuracy Class?

The accuracy class defines the maximum measurement error under specified operating conditions.

It includes:

  • Ratio error
  • Phase displacement error

Common CT Accuracy Classes

Class 0.2

High precision measurement.

Applications:

  • Laboratory measurement
  • High-accuracy revenue metering

Accuracy:

±0.2%


Class 0.5

Common industrial measurement grade.

Applications:

  • Energy monitoring
  • Industrial meters
  • Building EMS

Accuracy:

±0.5%


Class 0.5S

Higher precision metering class.

Advantages:

  • Better accuracy at low current
  • Improved phase performance

Applications:

  • Commercial billing
  • Precision energy monitoring

Class 1.0

General monitoring applications.

Applications:

  • Load monitoring
  • Basic power measurement

Accuracy Class Selection Guide

Application Recommended Accuracy
Energy monitoring Class 0.5
Commercial sub-metering Class 0.5S
Industrial monitoring Class 0.5
General indication Class 1.0
Revenue metering Class 0.2 / 0.5S

Chapter 10 — Metering CT vs Protection CT

Not all current transformers are designed for the same purpose.

A major distinction exists between:

  • Metering CT
  • Protection CT

Metering Current Transformer

Designed for accurate measurement during normal operation.

Purpose:

  • Energy measurement
  • Power monitoring
  • Billing

Characteristics:

  • High accuracy
  • Lower saturation point
  • Precise measurement range

Applications:

  • Energy meters
  • Smart meters
  • EMS systems

Protection Current Transformer

Designed to protect electrical equipment during fault conditions.

Purpose:

  • Detect abnormal currents
  • Trigger protection devices

Characteristics:

  • Higher saturation capability
  • Designed for fault currents

Applications:

  • Protection relays
  • Switchgear systems

Comparison

Feature Metering CT Protection CT
Purpose Measurement Protection
Accuracy Higher Lower
Normal Operation Excellent Moderate
Fault Current Handling Limited High
Application Meters Relays

Chapter 11 — Split Core Current Transformer Technology

Among all CT types, split core CTs have become increasingly popular because of their installation advantages.


What Is a Split Core CT?

A split core CT is a current transformer with a separable magnetic core.

The core can be opened and installed around an existing conductor without disconnecting the electrical system.


Traditional CT Installation

Traditional installation requires:

  1. Shut down power
  2. Disconnect conductor
  3. Install CT
  4. Reconnect system

Problems:

  • Production interruption
  • Higher labor cost
  • Safety risks

Split Core CT Installation

Process:

  1. Open CT clamp
  2. Place around conductor
  3. Close core
  4. Connect output terminals

Advantages:

  • No power shutdown
  • Fast installation
  • Suitable for retrofit
  • Lower installation cost

Why Engineers Choose Split Core CTs

1. Retrofit Projects

Existing buildings often cannot stop operation for electrical modifications.

Split core CTs solve this problem.

Applications:

  • Factories
  • Shopping malls
  • Hospitals
  • Data centers

2. Energy Monitoring Upgrades

Companies can add monitoring capability without replacing existing switchgear.


3. Limited Installation Space

Compact split core CT designs fit easily into:

  • Distribution panels
  • Control cabinets
  • Metering boxes

Chapter 12 — YADA Split Core Current Transformer Solutions

YADA provides split core CT solutions designed for intelligent energy monitoring systems.


SCT24L Series Split Core CT

Typical applications:

  • Smart energy meters
  • Industrial monitoring
  • Building energy management

Key advantages:

  • Easy installation
  • Compact design
  • High measurement accuracy
  • Retrofit-friendly structure

SCT40L Series Split Core CT

Designed for higher-current applications.

Suitable for:

  • Industrial distribution systems
  • Large feeders
  • Energy management projects

Features:

  • Multiple current ratios
  • High reliability
  • Industrial-grade design

Application Architecture

Typical YADA solution:

Electrical Feeder

↓

SCT24L / SCT40L Split Core CT

↓

Energy Meter

↓

RS485 Modbus RTU

↓

EMS Platform

↓

Energy Analytics

Chapter 13 — CT Burden Explained

Burden is another important CT specification.


What Is CT Burden?

Burden is the maximum load that the CT secondary can support while maintaining accuracy.

It is usually expressed in:

VA (Volt-Ampere)


Example

A CT specification:

400A/5A

Class 0.5

10VA

means:

The CT maintains Class 0.5 accuracy when the secondary load does not exceed 10VA.


Why Burden Matters

If the connected load exceeds the rated burden:

Problems may occur:

  • Increased measurement error
  • Phase displacement
  • Reduced accuracy

Factors Affecting CT Burden

Includes:

  • Cable length
  • Cable resistance
  • Meter input impedance
  • Connection devices

Long cable distances require careful burden calculation.


Chapter 14 — Common CT Selection Mistakes

Mistake 1 — Selecting CT Based Only on Maximum Current

Incorrect approach:

“The system is 400A, choose a 400A CT.”

Better approach:

Analyze:

  • Normal operating current
  • Peak load
  • Future expansion

Mistake 2 — Ignoring Accuracy Requirements

A low-cost CT may not provide sufficient accuracy for:

  • EMS
  • Energy billing
  • Efficiency analysis

Mistake 3 — Choosing Wrong Installation Type

Using solid core CTs in retrofit projects creates unnecessary downtime.


Mistake 4 — Ignoring Communication System Requirements

CT output must match the connected device.

Examples:

  • 5A CT output
  • 1A CT output
  • mA CT output

Chapter 15 — CT Selection Checklist

Before purchasing a current transformer, confirm:

Electrical Parameters

✔ Rated current
✔ Voltage level
✔ Frequency
✔ Short-circuit conditions


Measurement Requirements

✔ Accuracy class
✔ CT ratio
✔ Burden
✔ Phase error


Installation Requirements

✔ Solid core or split core
✔ Cable size
✔ Installation space
✔ Retrofit requirements


System Integration

✔ Energy meter compatibility
✔ EMS communication requirements
✔ Output signal type

Chapter 16 — Current Transformer vs Hall Effect Sensor

With the development of smart energy systems, engineers often compare traditional CTs with Hall effect current sensors.

Both measure electrical current, but their working principles and applications are different.


Current Transformer (CT)

A CT uses electromagnetic induction to measure AC current.

Advantages

✔ High measurement accuracy
✔ Excellent long-term stability
✔ Passive device (no external power required)
✔ Cost-effective for AC systems
✔ Widely standardized worldwide

Typical Applications

  • Energy meters
  • Power meters
  • Switchboards
  • Industrial monitoring
  • EMS systems

Hall Effect Current Sensor

A Hall sensor measures current by detecting the magnetic field generated by current flow.

It can measure:

  • AC current
  • DC current
  • AC/DC current

Advantages

✔ Measures DC current
✔ Compact size
✔ Electrical isolation
✔ Fast response

Applications:

  • EV chargers
  • Battery systems
  • Solar inverters
  • Energy storage systems

CT vs Hall Sensor Comparison

Feature Current Transformer Hall Sensor
Measurement Type AC AC/DC
Accuracy High High
Power Supply Passive Requires power
Cost Lower Higher
DC Measurement No Yes
Energy Metering Excellent Good
EV/BESS Limited Excellent

Which One Should You Choose?

Choose a current transformer when:

  • Measuring AC distribution systems
  • Monitoring energy consumption
  • Integrating with energy meters
  • Building EMS systems

Choose a Hall sensor when:

  • Measuring DC systems
  • Monitoring batteries
  • EV charging
  • Solar storage systems

Chapter 17 — Current Transformer vs Rogowski Coil

Another advanced current measurement technology is the Rogowski coil.


Rogowski Coil

A Rogowski coil is an air-core flexible sensor used for measuring rapidly changing currents.


Advantages

  • Flexible installation
  • Very large current measurement range
  • No magnetic saturation
  • Lightweight

Limitations

  • Requires signal conditioning
  • Lower accuracy for some energy metering applications
  • Higher system complexity

Comparison

Feature CT Rogowski Coil
Core Magnetic core Air core
Accuracy High Medium
Installation Fixed Flexible
Large Current Good Excellent
Energy Metering Excellent Limited
Protection Excellent Limited

Chapter 18 — Current Transformer Applications by Industry

Current transformers are essential components in modern electrical monitoring systems.


1. Industrial Manufacturing

Industrial facilities use CTs for:

  • Production line monitoring
  • Motor energy analysis
  • Machine-level measurement
  • Load optimization

Benefits

CT-based monitoring helps manufacturers:

  • Identify energy waste
  • Improve equipment efficiency
  • Reduce electricity costs
  • Implement ISO 50001 energy management

2. Solar PV Systems

Solar power plants require accurate current measurement for:

  • AC output monitoring
  • Grid connection measurement
  • Energy production analysis

Typical CT Installation Points

PV Panels

↓

Solar Inverter

↓

AC Distribution Cabinet

↓

Current Transformer

↓

Energy Meter

↓

Monitoring Platform

Benefits

  • Generation monitoring
  • Performance analysis
  • Fault detection
  • Energy reporting

3. EV Charging Infrastructure

The rapid growth of EV charging requires accurate current measurement.

CTs are used for:

  • Charger monitoring
  • Load balancing
  • Energy billing
  • Power management

Applications

  • Commercial charging stations
  • Fleet charging depots
  • Parking facilities

4. Data Centers

Data centers require extremely reliable power monitoring.

CT applications include:

  • UPS output monitoring
  • PDU branch monitoring
  • Rack power measurement

Benefits

  • Improve power utilization efficiency
  • Prevent overload
  • Support capacity planning
  • Improve operational reliability

5. Smart Buildings

Modern buildings use CTs for:

  • Tenant sub-metering
  • HVAC monitoring
  • Lighting control
  • Energy analytics

Chapter 19 — Current Transformer Standards

Selecting CT products requires attention to international standards.


IEC 61869 Series

The most important international standard for instrument transformers is:

IEC 61869

It defines requirements for:

  • Current transformers
  • Voltage transformers
  • Accuracy performance
  • Safety requirements

Key Standards Related to CT Applications

Standard Purpose
IEC 61869-1 General requirements for instrument transformers
IEC 61869-2 Additional requirements for current transformers
IEC 61010 Safety requirements for measurement equipment
IEC 62053 Electricity meter accuracy requirements
RoHS Environmental compliance
CE European safety and EMC compliance

Why Standards Matter

Certified CT products provide:

  • Reliable accuracy
  • Consistent performance
  • International acceptance
  • Easier project approval

This is especially important for:

  • EPC projects
  • Industrial automation
  • Renewable energy projects
  • Government facilities

Chapter 20 — How to Choose a Current Transformer Manufacturer

For engineering projects, selecting a CT supplier is not only about price.

Important evaluation factors include:


1. Product Range

A professional CT manufacturer should provide:

  • Solid core CT
  • Split core CT
  • Mini CT
  • Residual current CT
  • Hall current sensor

A broad product range allows better application matching.


2. Accuracy Capability

Check whether the supplier provides:

  • Class 0.2
  • Class 0.5
  • Class 0.5S
  • Class 1.0

3. Certification Capability

Important certifications include:

  • CE
  • UL
  • RoHS
  • IEC compliance

4. OEM / ODM Capability

For international projects, suppliers should support:

  • Customized ratios
  • Customized dimensions
  • Label customization
  • Packaging requirements

5. Production Capability

Evaluate:

  • Factory capacity
  • Quality control system
  • Testing equipment
  • Engineering support

Chapter 21 — YADA Current Transformer Solution Portfolio

As an intelligent energy measurement solution provider, YADA offers CT products designed for modern energy monitoring applications.


1. Split Core Current Transformer Series

SCT24L Series

Designed for:

  • Smart energy meters
  • Building energy monitoring
  • Retrofit applications

Key advantages:

✔ Compact structure
✔ Easy installation
✔ High accuracy
✔ No power interruption installation


SCT40L Series

Designed for:

  • Industrial feeders
  • Higher current monitoring
  • Distribution systems

Applications:

  • Factory energy monitoring
  • Commercial buildings
  • EMS projects

2. CTF Series Current Transformer

Suitable for:

  • Industrial measurement
  • Power monitoring systems
  • Electrical distribution

Features:

  • Stable performance
  • Multiple current ratios
  • Industrial reliability

3. Residual Current Transformer (ZCT Series)

Designed for:

  • Leakage detection
  • Ground fault monitoring
  • Electrical safety systems

Applications:

  • Industrial protection
  • Smart distribution systems

YADA CT + Energy Meter Solution

Complete architecture:

Electrical Distribution System

↓

YADA Current Transformer

↓

YADA Energy Meter

↓

RS485 Modbus RTU

↓

EMS / BMS / SCADA

↓

Energy Analytics

This integrated solution enables:

  • Real-time monitoring
  • Energy optimization
  • Remote management
  • Predictive maintenance

Chapter 22 — Frequently Asked Questions (FAQ)

1. What is the purpose of a current transformer?

A CT converts high AC current into a smaller measurable signal for safe monitoring and measurement.


2. Can a current transformer measure DC current?

No. Traditional CTs measure AC current only. DC applications require Hall sensors or specialized DC current transducers.


3. What CT ratio should I choose?

Select a ratio based on the normal operating current, not only maximum current.


4. What is the most common CT output?

Common outputs include:

  • 5A
  • 1A
  • mA output

5. What does Class 0.5 mean?

Class 0.5 indicates a maximum measurement error of approximately ±0.5% under specified conditions.


6. Are split core CTs accurate?

Yes. High-quality split core CTs can achieve industrial measurement accuracy suitable for energy monitoring.


7. Can split core CTs be installed without power shutdown?

Yes. This is one of their biggest advantages.


8. What industries use CTs?

Common industries:

  • Manufacturing
  • Solar PV
  • EV charging
  • Data centers
  • Commercial buildings

9. What is CT burden?

Burden is the maximum secondary load a CT can support while maintaining accuracy.


10. What certifications should CT products have?

Depending on market requirements:

  • IEC 61869
  • CE
  • UL
  • RoHS

Technical Glossary

Current Transformer (CT)

An instrument transformer that converts high AC current into a smaller measurable current.


Primary Current

The actual current flowing through the electrical circuit being measured.


Secondary Current

The output current generated by the CT.


CT Ratio

The relationship between primary and secondary current.


Accuracy Class

Defines the maximum measurement error of the CT.


Burden

The load connected to the CT secondary circuit.


Split Core CT

A CT with a separable core designed for easy installation.


Key Takeaways

  • Current transformers are essential components for safe and accurate electrical measurement.
  • CTs enable energy monitoring systems to measure high-current circuits without direct connection.
  • Correct selection requires considering:
    • CT ratio
    • Accuracy class
    • Burden
    • Installation method
    • Application requirements
  • Split core CTs are ideal for retrofit energy monitoring projects.
  • CTs are widely used in:
    • Industrial automation
    • Solar PV
    • EV charging
    • Data centers
    • Smart buildings
  • Selecting a reliable CT manufacturer ensures measurement accuracy, project reliability, and long-term system performance.

Summary

A current transformer (CT) is an electrical measurement device that converts high AC current into a smaller standardized current signal for safe monitoring by energy meters, protection devices, and EMS platforms. CTs are available in multiple types including solid core CTs, split core CTs, and residual current transformers. Key selection factors include current ratio, accuracy class, burden, and installation requirements. Industrial CT solutions are widely used in energy monitoring, solar PV systems, EV charging stations, data centers, and smart buildings.

Need the Right Current Transformer for Your Energy Monitoring Project?

YADA provides industrial-grade current transformer solutions for:

✔ Energy meters
✔ EMS systems
✔ Solar PV monitoring
✔ EV charging infrastructure
✔ Data center power monitoring
✔ Industrial energy management

With solutions including Split Core CT, Precision CT, and Residual Current Transformer, YADA helps global customers build reliable and accurate power monitoring systems.

Contact YADA engineering team for customized CT solutions, OEM support, and project recommendations.

something the matter? Contact us now!